Commit 1cd0d0e4 authored by Mukund Sivaraman's avatar Mukund Sivaraman

[1673] Decode exit status in boss

parent 14d4b5dd
......@@ -598,7 +598,7 @@ needs a dedicated message bus.
</varlistentry>
<varlistentry id="BIND10_COMPONENT_FAILED">
<term>BIND10_COMPONENT_FAILED component %1 (pid %2) failed with %3 exit status</term>
<term>BIND10_COMPONENT_FAILED component %1 (pid %2) failed: %3</term>
<listitem><para>
The process terminated, but the bind10 boss didn't expect it to, which means
it must have failed.
......
......@@ -24,7 +24,7 @@ needs a dedicated message bus.
An error was encountered when the boss module specified
statistics data which is invalid for the boss specification file.
% BIND10_COMPONENT_FAILED component %1 (pid %2) failed with %3 exit status
% BIND10_COMPONENT_FAILED component %1 (pid %2) failed: %3
The process terminated, but the bind10 boss didn't expect it to, which means
it must have failed.
......
......@@ -30,6 +30,8 @@ configuration). This is yet to be designed.
import isc.log
from isc.log_messages.bind10_messages import *
import time
import os
import signal
logger = isc.log.Logger("boss")
DBG_TRACE_DATA = 20
......@@ -45,6 +47,14 @@ STATE_DEAD = 'dead'
STATE_STOPPED = 'stopped'
STATE_RUNNING = 'running'
def get_signame(signal_number):
"""Return the symbolic name for a signal."""
for sig in dir(signal):
if sig.startswith("SIG") and sig[3].isalnum():
if getattr(signal, sig) == signal_number:
return sig
return "unknown signal"
class BaseComponent:
"""
This represents a single component. This one is an abstract base class.
......@@ -206,8 +216,30 @@ class BaseComponent:
it is considered a core or needed component, or because
the component is to be restarted later.
"""
if exit_code is not None:
if os.WIFEXITED(exit_code):
exit_str = "process exited normally with exit status %d" % (exit_code)
elif os.WIFCONTINUED(exit_code):
exit_str = "process continued with exit status %d" % (exit_code)
elif os.WIFSTOPPED(exit_code):
sig = os.WSTOPSIG(exit_code)
signame = get_signame(sig)
exit_str = "process stopped with exit status %d (killed by signal %d: %s)" % (exit_code, sig, signame)
elif os.WIFSIGNALED(exit_code):
if os.WCOREDUMP(exit_code):
exit_str = "process dumped core with exit status %d" % (exit_code)
else:
sig = os.WTERMSIG(exit_code)
signame = get_signame(sig)
exit_str = "process terminated with exit status %d (killed by signal %d: %s)" % (exit_code, sig, signame)
else:
exit_str = "unknown condition with exit status %d" % (exit_code)
else:
exit_str = "unknown condition"
logger.error(BIND10_COMPONENT_FAILED, self.name(), self.pid(),
exit_code if exit_code is not None else "unknown")
exit_str)
if not self.running():
raise ValueError("Can't fail component that isn't running")
self.__state = STATE_STOPPED
......